<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="other" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">Frontier Materials &amp; Technologies</journal-id><journal-title-group><journal-title xml:lang="en">Frontier Materials &amp; Technologies</journal-title><trans-title-group xml:lang="ru"><trans-title>Frontier Materials &amp; Technologies</trans-title></trans-title-group></journal-title-group><issn publication-format="print">2782-4039</issn><issn publication-format="electronic">2782-6074</issn><publisher><publisher-name xml:lang="en">Togliatti State University</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">560</article-id><article-id pub-id-type="doi">10.18323/2782-4039-2022-3-1-106-114</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Articles</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Статьи</subject></subj-group><subj-group subj-group-type="article-type"><subject></subject></subj-group></article-categories><title-group><article-title xml:lang="en">On the compatibility of surgical implants of bioresorbable magnesium alloys with medical devices of titanium alloys</article-title><trans-title-group xml:lang="ru"><trans-title>О совместимости хирургических имплантатов из биорезорбируемых магниевых сплавов с медицинскими изделиями из титановых сплавов</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7530-9518</contrib-id><name-alternatives><name xml:lang="en"><surname>Myagkikh</surname><given-names>Pavel N.</given-names></name><name xml:lang="ru"><surname>Мягких</surname><given-names>Павел Николаевич</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>junior researcher of the Research Institute of Advanced Technologies<bold><italic> </italic></bold></p></bio><bio xml:lang="ru"><p>младший научный сотрудник НИИ прогрессивных технологий</p></bio><email>feanorhao@gmail.com</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7063-088X</contrib-id><name-alternatives><name xml:lang="en"><surname>Merson</surname><given-names>Evgeny D.</given-names></name><name xml:lang="ru"><surname>Мерсон</surname><given-names>Евгений Дмитриевич</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>PhD (Physics and Mathematics), senior researcher of the Research Institute of Advanced Technologies<bold><italic> </italic></bold></p></bio><bio xml:lang="ru"><p>кандидат физико-математических наук, старший научный сотрудник НИИ прогрессивных технологий</p></bio><email>mersoned@gmail.com</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-0570-2584</contrib-id><name-alternatives><name xml:lang="en"><surname>Poluyanov</surname><given-names>Vitaly A.</given-names></name><name xml:lang="ru"><surname>Полуянов</surname><given-names>Виталий Александрович</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>PhD (Engineering), junior researcher of the Research Institute of Advanced Technologies</p></bio><bio xml:lang="ru"><p>кандидат технических наук<italic>,<bold> </bold></italic>младший научный сотрудник НИИ прогрессивных технологий</p></bio><email>vitaliy.poluyanov@gmail.com</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-5006-4115</contrib-id><name-alternatives><name xml:lang="en"><surname>Merson</surname><given-names>Dmitry L.</given-names></name><name xml:lang="ru"><surname>Мерсон</surname><given-names>Дмитрий Львович</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>Doctor of Sciences (Physics and Mathematics), Professor, Director of the Research Institute of Advanced Technologies</p></bio><bio xml:lang="ru"><p>доктор физико-математических наук, профессор, директор НИИ прогрессивных технологий</p></bio><email>D.Merson@tltsu.ru</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Begun</surname><given-names>Marina E.</given-names></name><name xml:lang="ru"><surname>Бегун</surname><given-names>Марина Эдуардовна</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>student, a technician of the Research Institute of Advanced Technologies</p></bio><bio xml:lang="ru"><p>студент, техник НИИ прогрессивных технологий</p></bio><email>feanorhao@gmail.com</email><xref ref-type="aff" rid="aff1"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en">Togliatti State University, Togliatti</institution></aff><aff><institution xml:lang="ru">Тольяттинский государственный университет, Тольятти</institution></aff></aff-alternatives><pub-date date-type="pub" iso-8601-date="2022-09-30" publication-format="electronic"><day>30</day><month>09</month><year>2022</year></pub-date><issue>3-1</issue><issue-title xml:lang="en"/><issue-title xml:lang="ru"/><fpage>106</fpage><lpage>114</lpage><history><date date-type="received" iso-8601-date="2022-09-30"><day>30</day><month>09</month><year>2022</year></date></history><permissions><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/"/></permissions><self-uri xlink:href="https://vektornaukitech.ru/jour/article/view/560">https://vektornaukitech.ru/jour/article/view/560</self-uri><abstract xml:lang="en"><p>Self-resorbable implants made of magnesium alloys, unlike the traditional implants made of titanium alloys and stainless steels, have the ability to completely dissolve in the human body, which makes it possible to eliminate the need for a recurrent operation to extract them. The issue of the possibility of using magnesium implants in the combination with products made of titanium alloys remains insufficiently studied at the moment. At the same time, it is widely known that the elements such as titanium and iron, with a potential more positive than magnesium, have a disastrous influence on the corrosion of magnesium alloys, since magnesium dissolves much faster due to the galvanic effect. This work is aimed to determine how the distance to a titanium implant affects the corrosion rate of a ZX10 magnesium alloy sample with an ultra-fine grain structure. As it is an issue of medical application, the authors carried out the corrosion tests within the conditions simulating the human body conditions: the corrosion medium circulation and keeping temperature within 37±1 °C. The authors used physiological solution as a corrosion medium. During corrosion testing, a titanium implant was placed in three, six, and twelve centimeters from the magnesium alloy sample; and the control tests were also carried out without a titanium implant. According to the obtained data, at a distance of 3 cm, the galvanic effect between titanium and magnesium manifests itself strongly, increasing the corrosion rate and the size of corrosion damage, but at a distance of 6 cm, the titanium implant does not have a visible effect on the corrosion of a sample.</p></abstract><trans-abstract xml:lang="ru"><p>Саморастворяющиеся имплантаты из магниевых сплавов, в отличие от традиционных имплантатов из титановых сплавов и нержавеющих сталей, обладают способностью полностью растворяться в теле человека, что позволяет обойтись без повторной операции по их извлечению. Вопрос о возможности использования магниевых имплантатов совместно с изделиями из титановых сплавов на данный момент остается в недостаточной мере изученным. В то же время широко известно, что элементы с более положительным электродным потенциалом, чем у магния, такие как титан и железо, пагубно влияют на коррозию магниевых сплавов, поскольку за счет гальванического эффекта растворение магния происходит существенно быстрее. Целью работы было установить, какое влияние на скорость коррозии образца из магниевого сплава ZX10 с ультрамелкозернистой структурой оказывает расстояние до титанового имплантата. Поскольку речь идет о медицинских приложениях, коррозионные испытания проводились в условиях, имитирующих условия внутри человеческого тела: циркуляция коррозионной среды и поддержание температуры 37±1 °C. В качестве коррозионной среды использовался физиологический раствор. Во время коррозионных испытаний титановый имплантат располагали в 3, 6 и 12 см от образца из магниевого сплава. Дополнительно были проведены испытания образцов контрольной группы без титанового имплантата. Согласно полученным данным при расстоянии между титаном и магнием в 3 см гальванический эффект ярко проявляется: увеличивается скорость коррозии и размер коррозионных повреждений, однако на расстоянии в 6 см титановый имплантат уже не оказывает видимого влияния на коррозию образца.</p></trans-abstract><kwd-group xml:lang="en"><kwd>magnesium alloys</kwd><kwd>ZX10</kwd><kwd>bioresorbable materials</kwd><kwd>corrosion</kwd><kwd>medical implants</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>магниевые сплавы</kwd><kwd>ZX10</kwd><kwd>биорезорбируемые материалы</kwd><kwd>коррозия</kwd><kwd>медицинские имплантаты</kwd></kwd-group><funding-group><funding-statement xml:lang="en">The study was financially supported by the Russian Foundation for Basic Research within the scientific project No. 20-38-90073 and by the Russian Science Foundation, project No. 20-19-00585.</funding-statement><funding-statement xml:lang="ru">Исследование выполнено при финансовой поддержке РФФИ в рамках научного проекта № 20-38-90073, а также при финансовой поддержке Российского научного фонда, проект № 20-19-00585.</funding-statement></funding-group></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><citation-alternatives><mixed-citation xml:lang="en">Prakasam M., Locs J., Salma-Ancane K., Loca D., Largeteau A., Berzina-Cimdina L. Biodegradable materials and metallic implants-A review. Journal of Functional Biomaterials, 2017, vol. 8, no. 4, article number 44. DOI: 10.3390/jfb8040044.</mixed-citation><mixed-citation xml:lang="ru">Prakasam M., Locs J., Salma-Ancane K., Loca D., Largeteau A., Berzina-Cimdina L. Biodegradable materials and metallic implants-A review // Journal of Functional Biomaterials. 2017. Vol. 8. № 4. Article number 44. DOI: 10.3390/jfb8040044.</mixed-citation></citation-alternatives></ref><ref id="B2"><label>2.</label><citation-alternatives><mixed-citation xml:lang="en">Antoniac I., Popescu D., Zapciu A., Antoniac A., Miculescu F., Moldovan H. Magnesium filled polylactic acid (PLA) material for filament based 3D printing. Materials, 2019, vol. 12, no. 5, article number 719. DOI: 10.3390/ma12050719.</mixed-citation><mixed-citation xml:lang="ru">Antoniac I., Popescu D., Zapciu A., Antoniac A., Miculescu F., Moldovan H. Magnesium filled polylactic acid (PLA) material for filament based 3D printing // Materials. 2019. Vol. 12. № 5. Article number 719. DOI: 10.3390/ma12050719.</mixed-citation></citation-alternatives></ref><ref id="B3"><label>3.</label><citation-alternatives><mixed-citation xml:lang="en">Knaack D., Goad M.E.P., Aiolova M., Rey C., Tofighi A., Chakravarthy P., Lee D.D. Resorbable calcium phosphate bone substitute. Journal of Biomedical Materials Research, 1998, vol. 43, no. 4, pp. 399–409. DOI: 10.1002/(SICI)1097-4636(199824)43:4&lt;399::AID-JBM7&gt;3.0.CO;2-J.</mixed-citation><mixed-citation xml:lang="ru">Knaack D., Goad M.E.P., Aiolova M., Rey C., Tofighi A., Chakravarthy P., Lee D.D. Resorbable calcium phosphate bone substitute // Journal of Biomedical Materials Research. 1998. Vol. 43. № 4. P. 399–409. DOI: 10.1002/(SICI)1097-4636(199824)43:4&lt;399::AID-JBM7&gt;3.0.CO;2-J.</mixed-citation></citation-alternatives></ref><ref id="B4"><label>4.</label><citation-alternatives><mixed-citation xml:lang="en">Teramoto H., Kawai A., Sugihara S., Yoshida A., Inoue H. Resorption of Apatite-wollastonite containing glass-ceramic and β-tricalcium phosphate in vivo. Acta Medica Okayama, 2005, vol. 59, no. 5, pp. 201–207. DOI: 10.18926/AMO/31974.</mixed-citation><mixed-citation xml:lang="ru">Teramoto H., Kawai A., Sugihara S., Yoshida A., Inoue H. Resorption of Apatite-wollastonite containing glass-ceramic and β-tricalcium phosphate in vivo // Acta Medica Okayama. 2005. Vol. 59. № 5. P. 201–207. DOI: 10.18926/AMO/31974.</mixed-citation></citation-alternatives></ref><ref id="B5"><label>5.</label><citation-alternatives><mixed-citation xml:lang="en">Poinern G.E.J., Brundavanam S., Fawcett D. Biomedical Magnesium Alloys: A Review of Material Properties, Surface Modifications and Potential as a Biodegradable Orthopaedic Implant. American Journal of Biomedical Engineering, 2021, vol. 2, no. 6, pp. 218–240. DOI: 10.5923/j.ajbe.20120206.02.</mixed-citation><mixed-citation xml:lang="ru">Poinern G.E.J., Brundavanam S., Fawcett D. Biomedical Magnesium Alloys: A Review of Material Properties, Surface Modifications and Potential as a Biodegradable Orthopaedic Implant // American Journal of Biomedical Engineering. 2021. Vol. 2. № 6. P. 218–240. DOI: 10.5923/j.ajbe.20120206.02.</mixed-citation></citation-alternatives></ref><ref id="B6"><label>6.</label><citation-alternatives><mixed-citation xml:lang="en">Levy G.K., Goldman J., Aghion E. The Prospects of Zinc as a Structural Material for Biodegradable Implants–A Review Paper. Metals, 2017, vol. 7, no. 10, article number 402. DOI: 10.3390/met7100402.</mixed-citation><mixed-citation xml:lang="ru">Levy G.K., Goldman J., Aghion E. The Prospects of Zinc as a Structural Material for Biodegradable Implants–A Review Paper // Metals. 2017. Vol. 7. № 10. Article number 402. DOI: 10.3390/met7100402.</mixed-citation></citation-alternatives></ref><ref id="B7"><label>7.</label><citation-alternatives><mixed-citation xml:lang="en">Schinhammer M., Hänzi A.C., Löffler J.F., Uggowitzer P.J. Design strategy for biodegradable Fe-based alloys for medical applications. Acta Biomaterialia, 2010, vol. 6, no. 5, pp. 1705–1713. DOI: 10.1016/j.actbio.2009.07.039.</mixed-citation><mixed-citation xml:lang="ru">Schinhammer M., Hänzi A.C., Löffler J.F., Uggowitzer P.J. Design strategy for biodegradable Fe-based alloys for medical applications // Acta Biomaterialia. 2010. Vol. 6. № 5. P. 1705–1713. DOI: 10.1016/j.actbio.2009.07.039.</mixed-citation></citation-alternatives></ref><ref id="B8"><label>8.</label><citation-alternatives><mixed-citation xml:lang="en">Merson D., Brilevsky A., Myagkikh P., Tarkova A., Prokhorikhin A., Kretov E., Frolova T., Vinogradov A. The functional properties of Mg-Zn-X biodegradable magnesium alloys. Materials, 2020, vol. 13, no. 3, article number 544. DOI: 10.3390/ma13030544.</mixed-citation><mixed-citation xml:lang="ru">Merson D., Brilevsky A., Myagkikh P., Tarkova A., Prokhorikhin A., Kretov E., Frolova T., Vinogradov A. The functional properties of Mg-Zn-X biodegradable magnesium alloys // Materials. 2020. Vol. 13. № 3. Article number 544. DOI: 10.3390/ma13030544.</mixed-citation></citation-alternatives></ref><ref id="B9"><label>9.</label><citation-alternatives><mixed-citation xml:lang="en">Merson D.L., Brilevsky A.I., Myagkikh P.N., Markushev M.V., Vinogradov A. Effect of deformation processing of the dilute Mg-1Zn-0.2Ca alloy on the mechanical properties and corrosion rate in a simulated body fluid. Letters on Materials, 2020, vol. 10, no. 2, pp. 217–222. DOI: 10.22226/2410-3535-2020-2-217-222.</mixed-citation><mixed-citation xml:lang="ru">Merson D.L., Brilevsky A.I., Myagkikh P.N., Markushev M.V., Vinogradov A. Effect of deformation processing of the dilute Mg-1Zn-0.2Ca alloy on the mechanical properties and corrosion rate in a simulated body fluid // Letters on Materials. 2020. Vol. 10. № 2. P. 217–222. DOI: 10.22226/2410-3535-2020-2-217-222.</mixed-citation></citation-alternatives></ref><ref id="B10"><label>10.</label><citation-alternatives><mixed-citation xml:lang="en">Tian L., Sheng Y., Huang L., Chow D.H.K., Chau W.H., Tang N., Ngai T., Wu C., Lu J., Qin L. An innovative Mg/Ti hybrid fixation system developed for fracture fixation and healing enhancement at load-bearing skeletal site. Biomaterials, 2018, vol. 180, pp. 173–183. DOI: 10.1016/j.biomaterials.2018.07.018.</mixed-citation><mixed-citation xml:lang="ru">Tian L., Sheng Y., Huang L., Chow D.H.K., Chau W.H., Tang N., Ngai T., Wu C., Lu J., Qin L. An innovative Mg/Ti hybrid fixation system developed for fracture fixation and healing enhancement at load-bearing skeletal site // Biomaterials. 2018. Vol. 180. P. 173–183. DOI: 10.1016/j.biomaterials.2018.07.018.</mixed-citation></citation-alternatives></ref><ref id="B11"><label>11.</label><citation-alternatives><mixed-citation xml:lang="en">Myagkikh P.N., Merson E.D., Poluyanov V.A., Merson D.L. In-situ study of corrosion process of biodegradable magnesium alloys. Vektor nauki Tolyattinskogo gosudarstvennogo universiteta, 2021, no. 2, pp. 18–25. DOI: 10.18323/2073-5073-2021-2-18-25.</mixed-citation><mixed-citation xml:lang="ru">Мягких П.Н., Мерсон Е.Д., Полуянов В.А., Мерсон Д.Л. In-situ исследование процесса коррозии магниевых биорезорбируемых сплавов // Вектор науки Тольяттинского государственного университета. 2021. № 2. С. 18–25. DOI: 10.18323/2073-5073-2021-2-18-25.</mixed-citation></citation-alternatives></ref><ref id="B12"><label>12.</label><citation-alternatives><mixed-citation xml:lang="en">Myagkikh P.N., Merson E.D., Poluyanov V.A., Merson D.L. Kinetics and evolution of corrosion failure of pure magnesium with various grain size: in-situ study. Materials. Technologies. Design, 2022, vol. 4, no. 1, pp. 39–47. DOI: 10.54708/26587572_2022_41739.</mixed-citation><mixed-citation xml:lang="ru">Мягких П.Н., Мерсон Е.Д., Полуянов В.А., Мерсон Д.Л. In-situ исследование кинетики и эволюции коррозионного разрушения чистого магния с разным размером зерна // Materials. Technologies. Design. 2022. Т. 4. № 1. С. 39–47. DOI: 10.54708/26587572_2022_41739.</mixed-citation></citation-alternatives></ref><ref id="B13"><label>13.</label><citation-alternatives><mixed-citation xml:lang="en">Song G. Control of biodegradation of biocompatable magnesium alloys. Corrosion Science, 2007, vol. 49, no. 4, pp. 1696–1701. DOI: 10.1016/j.corsci.2007.01.001.</mixed-citation><mixed-citation xml:lang="ru">Song G. Control of biodegradation of biocompatable magnesium alloys // Corrosion Science. 2007. Vol. 49. № 4. P. 1696–1701. DOI: 10.1016/j.corsci.2007.01.001.</mixed-citation></citation-alternatives></ref><ref id="B14"><label>14.</label><citation-alternatives><mixed-citation xml:lang="en">Xin Y., Liu C., Zhang X., Tang G., Tian X., Chu P.K. Corrosion behavior of biomedical AZ91 magnesium alloy in simulated body fluids. Journal of Materials Research, 2007, vol. 22, no. 7, pp. 2004–2011. DOI: 10.1557/jmr.2007.0233.</mixed-citation><mixed-citation xml:lang="ru">Xin Y., Liu C., Zhang X., Tang G., Tian X., Chu P.K. Corrosion behavior of biomedical AZ91 magnesium alloy in simulated body fluids // Journal of Materials Research. 2007. Vol. 22. № 7. P. 2004–2011. DOI: 10.1557/jmr.2007.0233.</mixed-citation></citation-alternatives></ref><ref id="B15"><label>15.</label><citation-alternatives><mixed-citation xml:lang="en">Li K.K., Wang B., Yan B., Lu W. Preparing Ca-P coating on biodegradable magnesium alloy by hydrothermal method: In vitro degradation behavior. Chinese Science Bulletin, 2012, vol. 57, no. 18, pp. 2319–2322. DOI: 10.1007/s11434-012-5067-5.</mixed-citation><mixed-citation xml:lang="ru">Li K.K., Wang B., Yan B., Lu W. Preparing Ca-P coating on biodegradable magnesium alloy by hydrothermal method: In vitro degradation behavior // Chinese Science Bulletin. 2012. Vol. 57. № 18. P. 2319–2322. DOI: 10.1007/s11434-012-5067-5.</mixed-citation></citation-alternatives></ref><ref id="B16"><label>16.</label><citation-alternatives><mixed-citation xml:lang="en">Li L.Y., Liu B., Zeng R.C., Li S.Q., Zhang F., Zou Y.H., Jiang H.G., Chen X.B., Guan S.K., Liu Q.Y. In vitro corrosion of magnesium alloy AZ31 - a synergetic influence of glucose and Tris. Frontiers of Materials Science, 2018, vol. 12, no. 2, pp. 184–197. DOI: 10.1007/s11706-018-0424-1.</mixed-citation><mixed-citation xml:lang="ru">Li L.Y., Liu B., Zeng R.C., Li S.Q., Zhang F., Zou Y.H., Jiang H.G., Chen X.B., Guan S.K., Liu Q.Y. In vitro corrosion of magnesium alloy AZ31 - a synergetic influence of glucose and Tris // Frontiers of Materials Science. 2018. Vol. 12. № 2. P. 184–197. DOI: 10.1007/s11706-018-0424-1.</mixed-citation></citation-alternatives></ref><ref id="B17"><label>17.</label><citation-alternatives><mixed-citation xml:lang="en">Makkar P., Sarkar S.K., Padalhin A.R., Moon B.G., Lee Y.S., Lee B.T. In vitro and in vivo assessment of biomedical Mg–Ca alloys for bone implant applications. Journal of Applied Biomaterials and Functional Materials, 2018, vol. 16, no. 3, pp. 126–136. DOI: 10.1177/2280800017750359.</mixed-citation><mixed-citation xml:lang="ru">Makkar P., Sarkar S.K., Padalhin A.R., Moon B.G., Lee Y.S., Lee B.T. In vitro and in vivo assessment of biomedical Mg–Ca alloys for bone implant applications // Journal of Applied Biomaterials and Functional Materials. 2018. Vol. 16. № 3. P. 126–136. DOI: 10.1177/2280800017750359.</mixed-citation></citation-alternatives></ref><ref id="B18"><label>18.</label><citation-alternatives><mixed-citation xml:lang="en">Liu M., Qiu D., Zhao M.C., Song G., Atrens A. The effect of crystallographic orientation on the active corrosion of pure magnesium. Scripta Materialia, 2008, vol. 58, no. 5, pp. 421–424. DOI: 10.1016/j.scriptamat.2007.10.027.</mixed-citation><mixed-citation xml:lang="ru">Liu M., Qiu D., Zhao M.C., Song G., Atrens A. The effect of crystallographic orientation on the active corrosion of pure magnesium // Scripta Materialia. 2008. Vol. 58. № 5. P. 421–424. DOI: 10.1016/j.scriptamat.2007.10.027.</mixed-citation></citation-alternatives></ref><ref id="B19"><label>19.</label><citation-alternatives><mixed-citation xml:lang="en">Zhang X., Ba Z., Wang Q., Wu Y., Wang Z., Wang Q. Uniform corrosion behavior of GZ51K alloy with long period stacking ordered structure for biomedical application. Corrosion Science, 2014, vol. 88, pp. 1–5. DOI: 10.1016/j.corsci.2014.07.004.</mixed-citation><mixed-citation xml:lang="ru">Zhang X., Ba Z., Wang Q., Wu Y., Wang Z., Wang Q. Uniform corrosion behavior of GZ51K alloy with long period stacking ordered structure for biomedical application // Corrosion Science. 2014. Vol. 88. P. 1–5. DOI: 10.1016/j.corsci.2014.07.004.</mixed-citation></citation-alternatives></ref><ref id="B20"><label>20.</label><citation-alternatives><mixed-citation xml:lang="en">Pogorielov M., Husak E., Solodivnik A., Zhdanov S. Magnesium-based biodegradable alloys: Degradation, application, and alloying elements. Interventional Medicine and Applied Science, 2017, vol. 9, no. 1, pp. 27–38. DOI: 10.1556/1646.9.2017.1.04.</mixed-citation><mixed-citation xml:lang="ru">Pogorielov M., Husak E., Solodivnik A., Zhdanov S. Magnesium-based biodegradable alloys: Degradation, application, and alloying elements // Interventional Medicine and Applied Science. 2017. Vol. 9. № 1. P. 27–38. DOI: 10.1556/1646.9.2017.1.04.</mixed-citation></citation-alternatives></ref></ref-list></back></article>
